Home | Products | Part Numbers | Design Kits | TECHNICAL INFO | Company | Career | Contacts | News    

         
 
   Specifications and Test Conditions*
 
NO
ITEM
TEST METHOD
SPECIFICATION
1 Appearance 

100% of the capacitor chips are inspected under the most modern automatic optical machine for the following categories:

  • Dimensions – overall size, termination bandwidth
  • Ceramic defects – chips, cracks, holes corners, color
  • Termination defects – straight edges, texture, holes, scratches
2 Capacitance
CAP.
Freq.
Voltage
Temp.
≤1nF
1MHz ± 5%
1.0±0.2 VRMS
25°C
> 1nF
1KHz ± 5%
1.0±0.2 VRMS
25°C
CAP.
Freq.
Voltage
Temp.
≤10µF
1KHz ± 5%
1.0±0.2 VRMS
25°C
> 10µF
120Hz ± 20%
1.0±0.2 VRMS
25°C

  

Within the specified tolerance
3 Dissipation Factor D.F. ≤ 0.0005
D.F. ≤ 0.0001 @ 1 MHz for P90
4 Insulation resistance
 
> 1000 25°C, WVDC (typical)
> 1 for Porcelain MLCC
5 Dielectric Withstanding Voltage  > 2.5 XWVDC
6  Solderability 62Sn/36Pb/2Ag solder at 240±5°C , Dip time = 5±1 Sec Solder coverage ≥ 90% of metallized areas
7  Resistance to
soldering heat
62Sn/36Pb/2Ag solder at 260±5°C , dip time =10±1Sec Sold coverage ≥80%. Chip should not crack
8  Termination adhesion A 2.0 Lbs. force in parallel shall be applied ot the line joining the termination for 10±1seconds. Termination should not pull off. Ceramic should remain undamaged
9  PCB deflection Glass epoxy PCB: 1mm deflection No mechanical damage
10  Life test 1000 hours, 125 °C, 200%  working voltage Cap. Change 2% or 0.5pF max. I.R.= initial value
11  Thermal shock 5 Cycles:30±3 minutes at -55 °C ; 3 minutes at 25 °C ; 30±3 minutes at 125°C ; 3min. at 25 °C
P90: MIL-STD-202 Method 107 Condition A
Cap. Change 2%,or 0.5pF max. I.R.= 70% of initial value
12  Moisture resistance
240 hours, 85% relative humidity, 85°C , 1.5 VDC

P90 follows MIL-STD-202 Method 103 Condition A

  No damage on appearance

Cap. <±5% or ±0.5pF
Q Q ≥ 300
I.R. ≥70% of initial value
13 Temperature coefficient -55°C ~ +125°C NPO:0 ± 30ppm/°C
P90: 90± 20ppm/°C
14 Aging Rate Perform a heat treatment at 150±10 oc for 1 hour and then set it at room temperature for 1.5±0.5 hours. Perform the initial measurement. Then perform the measurement after 10 hours, 100 hours and 1000 hours. None
* For aec NPO (S-Series) and Porcelain P-90 (P-Series)
 

 

 
 
 
 
 
 
 
 
 
         
 